Ares Make Up Air Unit: What It Is & How It Works

Updated November 20, 2026

Ares make up air unit refers to a product line of commercial and industrial ventilation equipment manufactured by Ares, a brand known for heating, ventilation, and air conditioning (HVAC) systems. In short, a make up air unit (MAU) is a dedicated device that brings in fresh outdoor air, conditions it (typically by heating, cooling, or filtering), and supplies it to a building to replace air that is exhausted by kitchen hoods, bathroom fans, or industrial processes. This article explains the purpose, components, selection criteria, and common issues with Ares make up air units, along with practical guidance for buyers and facility managers.

Why Make Up Air Units Are Necessary

Buildings with powerful exhaust systems—like commercial kitchens, paint booths, or manufacturing plants—remove large volumes of indoor air. Without a replacement air supply, the building becomes negatively pressurized. This causes problems:

  • Exhaust fans lose efficiency because they work against the pressure difference.
  • Smoke, odors, and fumes can be pulled back into occupied spaces.
  • Doors become hard to open, and drafts enter through gaps.
  • Backdrafting of combustion appliances (like gas water heaters) can occur, posing a carbon monoxide hazard.

A make up air unit solves this by actively supplying outdoor air to balance the pressure. Ares units are designed to handle these demands in commercial settings, offering robust construction and control options.

How an Ares Make Up Air Unit Works

The core function is simple: an MAU draws in outside air, conditions it, and delivers it into the building. Ares units typically include the following components:

  • Intake damper and filter section – Controls the amount of outdoor air and removes particulates.
  • Heating section – Can be gas-fired, electric, or hot water coil. Gas-fired units use a burner to heat air directly; electric units use resistance coils; hydronic coils use boiler water.
  • Cooling section (optional) – For climates where summer cooling is needed, some Ares units include DX (direct expansion) or chilled water coils.
  • Supply fan – Pushes the conditioned air into the ductwork. Fans can be forward-curved centrifugal or vane-axial, depending on static pressure requirements.
  • Controls – Thermostats, pressure sensors, and building management system (BMS) interfaces regulate operation. Many Ares units come with factory-mounted controls for simple commissioning.

When the exhaust system runs, a pressure sensor or a signal from the exhaust fan triggers the MAU to open its damper and turn on the fan. The heating or cooling coil modulates to maintain the desired supply air temperature.

Choosing the Right Ares Make Up Air Unit

Selecting an MAU requires matching the unit to the building’s specific airflow and heating/cooling loads. Key factors to consider:

  1. Airflow rate (CFM) – The unit must supply at least as much air as is exhausted. Measure the total exhaust capacity of all fans that operate simultaneously. For example, a restaurant with a 2,000 CFM range hood needs a 2,000 CFM MAU, but often 10–15% extra is added for positive pressure.
  2. Heating capacity – Calculate the temperature rise needed to bring outdoor air to a comfortable supply temperature (typically 65–70°F). This depends on the coldest outdoor winter temperature and the airflow. A gas-fired unit is rated in BTU/hr.
  3. Fuel type – Natural gas is common for large units because it is economical. Electric is simpler but costlier to operate. Hot water coils are used when a boiler is already present.
  4. Mounting and configuration – Ares offers indoor and outdoor (weatherproof) units. Outdoor units have rain hoods and corrosion-resistant cabinets. Indoor units need a mechanical room with duct connections.
  5. Controls and code compliance – Many jurisdictions require MAUs to have carbon monoxide sensors and interlock with exhaust fans. Check local codes.

Always consult an HVAC engineer or a qualified contractor to perform a load calculation, as undersized units fail to maintain pressure, and oversized units waste energy.

Common Problems and Maintenance

Like any mechanical system, Ares MAUs can develop issues. The most frequent are:

  • Dirty filters – Clogged filters reduce airflow and strain the fan. Replace filters quarterly or more often in dusty environments.
  • Damper failures – The intake damper may stick or the actuator may fail, leading to no air supply or uncontrolled leakage. Lubricate moving parts and check linkage.
  • Gas burner issues – In gas-fired units, ignition failures or flame sensor problems cause lockouts. Have a licensed technician inspect the burner annually.
  • Fan belt wear – Belt-driven fans need periodic tensioning and replacement. Squealing or slipping indicates a problem.
  • Frost and ice – In cold climates, the intake can freeze if the damper leaks or if the unit runs without heat. Some units have a frost protection thermostat.

Regular preventive maintenance—including checking belts, cleaning coils, testing safeties, and verifying airflow—extends the life of the unit and avoids costly downtime.

Comparing Ares to Other Brands

In the MAU market, Ares competes with established names like Greenheck, CaptiveAire, and Modine. Ares units are often positioned as cost-effective options for light commercial applications, such as restaurants and small warehouses. While Greenheck and CaptiveAire offer extensive custom engineering and a wide range of accessories, Ares provides simpler, pre-engineered packages that are easier to specify and install. However, availability of parts and local service can vary by region, so check with local distributors. For complex projects with high static pressure or specialized controls, a custom manufacturer may be more suitable.

Costs and Energy Considerations

The price of an Ares MAU depends on size, heating type, and options. As a rough guide, a 2,000 CFM gas-fired unit might cost between $8,000 and $15,000 installed, while a 10,000 CFM unit can exceed $30,000. Operating costs are dominated by heating fuel. For example, heating 2,000 CFM of outdoor air from 20°F to 70°F for 8 hours a day in a heating climate can use roughly 1.5 million BTUs per day, which at $1.50 per therm costs about $22 per day. Energy recovery wheels or heat pipes can pre-condition incoming air, reducing fuel consumption by 50–70%. Many Ares units can be fitted with such options, though they increase upfront cost. Also, consider variable frequency drives (VFDs) on fans to match airflow to demand, saving electricity.

Safety and Code Compliance

Make up air units must comply with building and fire codes. Key safety points:

  • Gas-fired units require proper combustion air and venting. Install per manufacturer instructions and local codes.
  • Units must be interlocked with exhaust fans so that the MAU cannot run when exhaust is off (to avoid over-pressurization) and vice versa.
  • In restaurants, the MAU must not interfere with fire suppression systems. Ducts and dampers may need fire-rated construction.
  • Carbon monoxide detectors should be installed in areas near combustion equipment, and the MAU should provide adequate ventilation to prevent buildup.

Always have a licensed HVAC professional perform installation and annual inspections to ensure safe operation.

Frequently Asked Questions

What is the difference between a make up air unit and an air handler?
An air handler (AHU) typically recirculates indoor air, conditioning it and distributing it, with a small percentage of outdoor air for ventilation. A make up air unit is dedicated to bringing in 100% outdoor air to replace exhausted air. It often has a larger heating capacity because it must heat cold outdoor air.

Can I use a make up air unit for cooling?
Yes, some MAUs include a cooling coil (DX or chilled water) to temper supply air in summer. However, many buildings rely on separate air conditioning systems for occupied spaces, and the MAU only needs to supply neutral air (around 70°F) to avoid drafts.

How do I know what size MAU I need?
Calculate the total exhaust CFM from all hoods and fans that run simultaneously. The MAU should supply at least that amount, often 10% more to maintain slight positive pressure. For precise sizing, use Manual J or a commercial load calculation, and consult an engineer.

Can a make up air unit be installed outdoors?
Yes, many Ares units are weatherproof and designed for rooftop or ground-level outdoor installation. They come with rain hoods, corrosion-resistant cabinets, and sometimes winterization packages for cold climates.

Does a make up air unit filter the air?
Most units have a basic filter (typically MERV 8 or 13) to remove dust and particulates. Higher efficiency filters can be added for better indoor air quality, but they increase static pressure and may require a more powerful fan.

What happens if the MAU is undersized?
An undersized MAU will not fully replace exhausted air, leaving the building under negative pressure. This reduces exhaust effectiveness, causes drafts, and can lead to backdrafting of combustion appliances. To fix it, you may need to add a second unit or reduce exhaust capacity.