Apollo XP65 Smoke Detector: Facts & Setup

Updated November 21, 2026

The Apollo XP65 smoke detector is a real, widely installed addressable smoke sensor, but it is not a standalone alarm you can buy at a hardware store—it is a component of an Apollo protocol-based fire alarm control panel, most commonly the XP95 or Discovery family. It detects smoke using an optical chamber and reports a value back to the control panel, which then decides whether to raise an alarm. This article explains what the XP65 actually is, how it works, how it differs from other Apollo detectors, and what you need to know if you are maintaining or replacing one.

What Is the Apollo XP65?

The XP65 is an optical (photoelectric) smoke sensor manufactured by Apollo Fire Detectors, a UK-based company whose addressable devices are used in commercial and industrial fire alarm systems worldwide. The “XP” stands for the XP95 protocol, Apollo’s analogue addressable communication system, and “65” refers to the device’s part number in that family. The XP65 is designed to be connected to a two-wire loop that carries both power and data to and from a control panel. Unlike a domestic smoke alarm, the XP65 has no built-in sounder and cannot operate on its own—it only works with a compatible Apollo control panel, such as those made by Kentec, Morley, or Advanced, or with Apollo’s own XP95 range.

How the XP65 Detects Smoke

The XP65 uses a light-scattering principle. Inside the detector’s chamber, an infrared LED shines light across a dark space. A photodiode sits at an angle so that it does not receive light directly from the LED. When smoke particles enter the chamber, they scatter the light, and some of it reaches the photodiode. The detector then converts the amount of scattered light into an analogue value (typically 0–255) and sends it to the control panel. The panel continuously monitors this value and can be programmed to trigger an alarm at a specific threshold, usually around 30–40% obscuration per metre, though the exact setting depends on the system design. This analogue reporting allows the panel to distinguish between a slow smouldering fire (gradual rise) and a sudden burst of smoke (sharp rise), which helps reduce false alarms while still responding quickly to real fires.

XP65 vs. XP95 and Discovery: What’s the Difference?

Apollo’s addressable range includes several families, and the XP65 is often confused with newer models. The XP95 family (which includes the XP95 optical detector, part number 55000-200) uses the same protocol but has a different mechanical design and a separate base. The XP65 is actually an older, discontinued product that was superseded by the XP95. The Discovery range (e.g., Discovery optical detector, 58000-200) is a later, more advanced family with drift compensation and a wider analogue range. If you have an XP65 in the field, it is likely from a system installed in the 1990s or early 2000s. You cannot simply replace an XP65 with a Discovery detector without changing the base and possibly the control panel firmware, because the addressing and communication protocols differ. Always check the detector’s marking: the XP65 typically has a part number printed on the side, such as 55000-100 or 55000-101, depending on the version.

How to Identify and Test an XP65

To identify an XP65, look for a white, round detector head with a small LED indicator that flashes when the panel polls it. The base is a separate component, often a standard XP95 base (part 45681-200) that the detector twists into. To test the detector, you can use a dedicated smoke test aerosol (e.g., Solo A5) or a magnet. Apollo provides a test magnet that, when held against the detector’s test point, forces the device to send a fire alarm value to the panel. You can also use a multi-meter to check the loop voltage (typically 17–28 V DC) at the base. However, do not open the detector chamber—it is sealed to prevent dust ingress, and opening it will void the warranty and may cause false alarms.

Common Problems and Maintenance

Like all optical smoke detectors, the XP65 is prone to false alarms from dust, insects, or steam. Over time, the chamber can accumulate dirt, which raises the baseline analogue value and can cause nuisance alarms. Apollo recommends cleaning detectors periodically, but because the XP65 is sealed, cleaning usually means replacing the detector head. A common issue is that the detector’s LED stops flashing, which indicates a communication fault—check the wiring and the base contacts. Another problem is that the detector may go into “drift compensation” mode if the panel supports it, but the XP65 itself does not have built-in drift compensation (that came with Discovery). If you see a fault on the panel, first try reseating the detector in its base. If that fails, swap the detector with a known-good unit to isolate the problem.

Replacing an XP65: What You Need to Know

If you need to replace an XP65, you have two options: find an original spare (harder now, as they are obsolete) or upgrade to a compatible modern detector. The safest upgrade path is to use an XP95 optical detector (55000-200) with the same base, because the XP95 is electrically and mechanically compatible with the XP65 base and protocol. The XP95 is still in production and is a drop-in replacement for most XP65 installations, provided the control panel firmware supports the XP95 protocol (most do, since the XP65 and XP95 share the same communication format). However, you should always verify with the panel manufacturer or a qualified fire alarm engineer before swapping detectors, because some older panels may not recognise the newer device’s analogue range. If you are upgrading the entire system, consider the Discovery range, which offers better false-alarm immunity and diagnostic features, but this requires changing the bases and possibly the control panel.

Cost and Where to Buy

Because the XP65 is obsolete, you will not find it in mainstream online stores. Second-hand units may appear on auction sites, but buying used fire safety equipment is risky—you cannot be sure of its age or calibration. A new XP95 optical detector typically costs between $15 and $30 (or £10–£20) from fire safety suppliers, and the base is about $5–$10. If you need a complete replacement head and base, budget around $25–$40 per point. Always purchase from a reputable supplier that can provide a certificate of conformity, and ensure the detector carries the CE mark and, where applicable, the UKCA mark. For a full system upgrade to Discovery, costs rise significantly because you must replace all detectors and bases, and possibly the control panel, which can run into hundreds or thousands of dollars depending on the size of the building.

Safety and Legal Considerations

Working on a fire alarm system is not a DIY task. In many jurisdictions, including the UK and most US states, only certified technicians are legally allowed to install, modify, or replace fire alarm components, because the system must comply with local codes (e.g., BS 5839 in the UK, NFPA 72 in the US). Incorrect installation can lead to the detector failing to operate during a fire, which is a serious safety risk. If you are a building owner or manager, always hire a qualified fire alarm engineer to carry out any work on an XP65 or its replacement. They will also test the system after installation to ensure it meets the required response times. Remember that an optical smoke detector like the XP65 is not suitable for all locations—for example, in kitchens or areas with heavy steam, a heat detector or a multi-sensor detector may be more appropriate. Always follow the manufacturer’s guidelines and the system design specification.

Frequently Asked Questions

Is the Apollo XP65 the same as a standard smoke alarm? No. The XP65 is an addressable detector that requires a control panel to operate. It has no built-in siren and cannot work as a standalone device. A standard smoke alarm is a self-contained unit with its own power and sounder.

Can I replace an XP65 with a Discovery detector? Not directly. The Discovery detector uses a different base and a more advanced communication protocol. You would need to change the base and ensure the control panel supports Discovery. For a simple swap, use an XP95 optical detector, which is backward-compatible with the XP65 base.

How do I know if my XP65 is faulty? Common signs include the LED not flashing, the control panel reporting a fault or “dirty” status, or frequent false alarms. You can test it with a magnet or smoke aerosol, but if you are unsure, call a technician.

Why does my XP65 keep giving false alarms? The most likely cause is dust or insects inside the optical chamber. Because the chamber is sealed, cleaning is not possible; you will need to replace the detector head. Steam or cooking fumes can also trigger it if it is installed too close to a kitchen.

Is the XP65 still legal to use? Yes, as long as the system is maintained and tested according to local regulations. However, because the detector is obsolete, replacement parts may be hard to find, and some insurance companies may require upgrades to newer equipment. It is always best to consult a fire safety professional.