The Apollo Series 65 is a widely used range of conventional smoke and heat detectors, primarily installed in commercial and industrial fire alarm systems across Europe and many other regions. These detectors are known for their reliable optical (photoelectric) sensing technology, robust build, and simple two-wire connection, making them a standard choice for many fire safety installers.
Background and History
The Series 65 range was developed by Apollo Fire Detectors, a UK-based company that has been manufacturing fire detection equipment since the 1980s. The Series 65 was introduced in the late 1980s as a successor to earlier conventional detectors, and it quickly became one of the most popular detector ranges in the UK and Europe. Its design was notable for its ease of installation and maintenance, with a common base that could be used across the entire range. Over the decades, the Series 65 has been installed in countless buildings, from schools and offices to industrial facilities, and it remains in production today, though newer ranges like the Apollo XP95 and Soteria have been introduced. The Series 65 is often described as a “conventional” detector, meaning it does not communicate digitally with the control panel; instead, it simply changes its electrical resistance when it detects smoke or heat, allowing the panel to identify which zone (a group of detectors) is activated.
How the Series 65 Works
The optical smoke detector in the Series 65 range uses a light-scattering principle. Inside the detector, there is a light-emitting diode (LED) and a photodiode (light sensor) arranged at an angle. In a normal state, the light from the LED does not reach the photodiode. When smoke particles enter the detection chamber, they scatter the light, causing some of it to hit the photodiode, which triggers the alarm. This type of detection is particularly effective for slow-burning, smouldering fires that produce large smoke particles, such as those from upholstery or electrical wiring.
The range also includes heat detectors, which use a thermistor to sense a rapid rise in temperature or a fixed temperature threshold (typically 58°C or 78°C). Heat detectors are used in areas where smoke detectors would cause false alarms, such as kitchens or dusty environments. All Series 65 detectors are designed to operate on a 12-24V DC supply and draw a low quiescent current (around 40 µA), making them compatible with most conventional fire alarm panels.
Choosing the Right Series 65 Detector
Selecting the correct detector for your application is crucial for fire safety. The Series 65 range includes several variants, each suited to specific environments:
- Optical Smoke Detector (Model 55000-100) – Best for general use in offices, corridors, and living areas where smouldering fires are likely.
- Heat Detector (Model 55000-200) – Suitable for kitchens, garages, and boiler rooms where smoke or steam would cause false alarms.
- Optical Smoke Detector with Remote Indicator (Model 55000-105) – Includes a terminal for connecting a remote LED, useful for hidden detectors.
- Heat Detector with Remote Indicator (Model 55000-205) – Similar to the above but for heat detection.
When choosing, consider the environment: if the area is prone to dust, steam, or cooking fumes, a heat detector is safer to avoid nuisance alarms. For general living and working spaces, an optical smoke detector is recommended. Always check the manufacturer’s data sheet for the operating temperature range and IP rating (the Series 65 typically has an IP23 rating, meaning it is protected against spraying water, but not submersion).
Installation and Wiring
Installing a Series 65 detector is straightforward, but it must be done correctly to ensure reliability. The detector consists of a base (which is wired to the fire alarm loop) and the detector head (which plugs into the base). The base has terminals for positive, negative, and (on some models) a remote indicator connection. Wiring is typically done with fire-resistant cable, and the loop is connected to a conventional fire alarm control panel.
Here are the basic steps for installation:
- Fix the base to the ceiling or wall, ensuring it is level and at least 300mm from any wall or obstruction.
- Connect the positive and negative wires to the corresponding terminals on the base.
- If using a remote indicator, connect its wire to the designated terminal.
- Plug the detector head into the base and twist it clockwise until it locks.
- Test the detector using the built-in test button or a suitable aerosol smoke tester.
It is essential to follow local fire safety regulations and the control panel manufacturer’s instructions. The detector should be positioned on the ceiling, ideally in the centre of the room, and at least 500mm away from any light fittings or air conditioning vents to avoid false alarms.
Common Problems and Troubleshooting
Like any electronic device, Series 65 detectors can develop faults. The most common issue is false alarms, often caused by dust accumulation, insects, or steam. Regular cleaning with a vacuum cleaner or a soft brush can help, but never use water or solvents. Another common problem is the detector failing to respond to a test; this may be due to a low battery (though the Series 65 is mains-powered, the detector head contains a backup battery in some models) or a wiring fault. If the detector beeps or flashes its LED intermittently, it may indicate a fault or that it needs cleaning.
If a detector is faulty, it should be replaced immediately. The Series 65 is designed to be easily replaceable; you can simply unplug the old head and plug in a new one, as long as it is the same type. Always use genuine Apollo parts to maintain compatibility and safety standards.
Comparison with Other Apollo Ranges
Apollo offers several detector ranges, and it can be confusing to know which one to choose. The Series 65 is a conventional detector, meaning it is used with conventional panels that divide the building into zones. In contrast, the XP95 and Soteria ranges are addressable detectors, meaning each detector has a unique address and can be individually identified by the control panel. Addressable systems are more expensive but offer better fault diagnostics and are often used in larger or more complex buildings.
The Series 65 is generally cheaper and simpler, making it a cost-effective choice for smaller installations. However, it lacks the advanced features of addressable systems, such as drift compensation (which adjusts for dust build-up) and remote configuration. For most small to medium-sized buildings, the Series 65 is perfectly adequate.
Cost and Maintenance
The cost of a Series 65 detector is relatively low, typically ranging from $15 to $30 per unit, depending on the model and supplier. The base costs a few dollars more. Installation costs will vary depending on the electrician and the complexity of the system. Maintenance is minimal: detectors should be cleaned every six months to a year, and tested regularly to ensure they are working. The manufacturer recommends that detectors be replaced after 10 years of service, as the sensors can degrade over time.
It is also important to note that the Series 65 is not compatible with all fire alarm panels; it is designed to work with conventional panels that support a compatible detector protocol. Always check the panel’s compatibility list before purchasing.
Safety and Compliance
The Series 65 detectors are certified to EN 54-7 (for smoke detectors) and EN 54-5 (for heat detectors), which are European standards for fire detection and fire alarm systems. They are also CE marked, indicating compliance with EU safety requirements. When installing a fire alarm system, it is crucial to comply with local building codes and fire safety regulations, which often specify the type and placement of detectors. For example, in the UK, BS 5839-1 provides guidance on the design, installation, and maintenance of fire alarm systems.
Always ensure that detectors are not painted over, as this can block the sensor and prevent operation. If you are in any doubt about installation or maintenance, consult a qualified fire safety engineer.
Frequently Asked Questions
Can I use a Series 65 detector with my existing alarm panel? It depends on your panel. The Series 65 is a conventional detector, so it must be used with a conventional panel that supports the same protocol. Check the panel’s documentation or consult a professional.
How do I clean a Series 65 smoke detector? Remove the detector head from the base, then gently vacuum the outside and the internal chamber using a soft brush attachment. Do not use water, solvents, or compressed air, as these can damage the sensor.
Why does my Series 65 detector keep beeping? A beeping detector usually indicates a low battery (if it has a backup battery) or a fault condition. Try replacing the battery (if applicable) or cleaning the detector. If the beeping persists, the detector may need to be replaced.
What is the difference between an optical and a heat detector? An optical detector uses a light beam to detect smoke particles, making it sensitive to smouldering fires. A heat detector responds to temperature changes, making it less prone to false alarms from steam or dust. Use heat detectors in kitchens and garages, and optical detectors in living areas.
How often should I test my Series 65 detector? You should test the detector at least once a month using the test button or a smoke aerosol. Additionally, have a professional inspect the entire system annually to ensure it meets safety standards.