The Apollo Series 65 optical smoke detector is a well-established analogue addressable smoke sensor that uses a light-scattering (photoelectric) principle to detect slow, smouldering fires. It is part of the Series 65 range, a family of detectors widely used in commercial and industrial fire alarm systems, known for its reliability and compatibility with a broad range of control panels.
Background and Development
The Series 65 range was introduced by Apollo Fire Detectors, a UK-based manufacturer, as an evolution of their earlier analogue detectors. The optical model (model number 55000-217 for the standard version) was designed to offer a cost-effective, stable solution for detecting fires that produce large smoke particles, typical of smouldering materials like overheated wiring, foam upholstery, or paper. Unlike ionisation detectors, which respond well to fast-flaming fires with small particles, optical detectors are less prone to nuisance alarms from cooking fumes or steam, making them a popular choice for general building protection.
The Series 65 platform was developed in the late 1980s and became a global standard, particularly in Europe and Asia, due to its simple two-wire connection and its ability to work with both conventional and addressable systems through interface units. Over the decades, it has been superseded by Apollo’s newer XP95 and Soteria ranges, but the Series 65 remains in widespread service, with a large installed base and ongoing availability of spare parts.
How It Works
Inside the detector’s sensing chamber, an infrared LED and a photodiode are positioned at an angle so that light from the LED does not normally reach the photodiode. When smoke enters the chamber, the smoke particles scatter the light, and some of it hits the photodiode, generating a signal. The detector’s electronics then compare this signal to a pre-set threshold, and if the level exceeds it for a sustained period, the detector sends an alarm signal to the control panel.
Key technical features include:
- Analogue addressable communication: The detector transmits a continuous analogue value (0–255) representing smoke density, allowing the panel to make decisions based on drift compensation and programmable alarm thresholds.
- Remote indicator support: A remote LED can be connected via the base terminals for visible alarm indication in high-ceiling or concealed locations.
- Drift compensation: The detector’s firmware (or the panel) can adjust for slow contamination build-up, reducing false alarms while maintaining sensitivity.
- Polling and addressing: Each detector has a unique address set by a DIP switch or via the panel, enabling precise location identification.
The optical chamber is designed to be resistant to ambient light and insects, with a fine mesh that prevents most dust and bugs from entering, though it is not fully sealed.
Choosing the Right Model
When selecting an Apollo Series 65 optical smoke detector, consider the environment and the system requirements. The main variants include:
- Standard optical (55000-217): For general indoor use in offices, corridors, and retail spaces.
- Optical with heat (55000-317): Combines optical smoke sensing with a thermistor for rate-of-rise and fixed-temperature detection, useful in areas with high ambient smoke or where a dual-response is needed.
- Marine version: Coated with a protective lacquer for use in salty or humid environments, such as ships or coastal buildings.
Also decide between the standard base (e.g., Series 65 base) and a relay base or isolator base. An isolator base is essential for loop systems where a short circuit on one device should not disable the entire loop. For most installations, the standard base suffices, but if the detector is placed in a harsh environment, consider the marine version or a detector with a higher IP rating.
Common Problems and Maintenance
Despite its reliability, users report several recurring issues:
- Dust contamination: Over time, dust accumulates on the LED or photodiode, causing the analogue value to drift upward. This can lead to false alarms or a “dirty” status on the panel. Regular cleaning with a vacuum cleaner (using a soft brush) or replacement of the chamber is recommended.
- Incorrect addressing: If the DIP switches are set incorrectly, the panel may not recognise the device. Always double-check the address against the panel’s configuration.
- LED not illuminating: The detector’s internal LED should flash every 4 seconds in normal operation. If it does not, check the base wiring and the detector’s seating.
- Moisture ingress: In humid areas, condensation can form inside the chamber, causing false alarms. The marine version or a sealed detector is a better choice for such environments.
Maintenance is straightforward: test the detector monthly using a magnet or a test smoke aerosol, and clean the chamber annually. Most detectors have a removable cover for easy access to the chamber.
Comparison with Other Apollo Ranges
Apollo’s newer XP95 and Soteria ranges offer several advantages over the Series 65, but they are not directly interchangeable. The XP95 uses a similar analogue protocol but has a different mechanical design and is not backward-compatible with Series 65 bases. The Soteria range adds advanced features like multi-criteria detection (optical, heat, and CO in one unit) and a more modern aesthetic.
For existing installations, sticking with Series 65 is often the most practical choice because replacing the entire loop would be costly. However, for new projects, many installers now choose Soteria due to its improved false-alarm immunity and wider environmental tolerance. The Series 65 remains a robust, proven solution, but it is now considered a legacy product.
Cost and Availability
Prices vary by region and supplier, but a single Series 65 optical detector typically costs between $20 and $40 USD, with bases adding another $5–$10. The marine version and the optical/heat combination are slightly more expensive. Because the range is still in production (as of the mid-2020s), replacement detectors are readily available from fire safety distributors and online marketplaces. However, as Apollo phases out the range, prices may rise for genuine parts, so it is wise to stock spares if you have a large installed base.
Safety and Compliance
When installing or replacing these detectors, always follow local fire codes and the manufacturer’s instructions. Key points:
- Mount detectors on ceilings at least 50 cm from walls, and avoid placing them near air vents or in dead air spaces.
- Do not paint the detector or its cover, as this blocks the smoke entry.
- Test after installation and at regular intervals, using the recommended test magnet or aerosol.
- Ensure the control panel is configured for the correct device type and address.
In many jurisdictions, fire alarm systems must be installed and maintained by certified professionals. The Series 65 detector is approved to EN 54-7 (European standard for smoke detectors) and has various national approvals, but always verify that the specific model meets your local regulations.
Frequently Asked Questions
Can I use a Series 65 optical detector with a conventional (non-addressable) panel? No, the Series 65 is an analogue addressable device. To use it on a conventional panel, you would need an addressable interface module, which is not practical. For conventional systems, Apollo offers the ORB series or other conventional detectors.
How do I know if my detector is faulty? The detector’s LED should flash every 4 seconds. If it is solid on, off, or flashing at a different rate, it may be faulty or in alarm. The panel will also show a fault or alarm status. A dirty detector may show a “maintenance” signal on the panel.
What is the difference between the optical and the optical/heat model? The optical/heat model (55000-317) contains a thermistor that measures temperature. It can be programmed to respond to a fixed temperature (e.g., 58°C) or a rate-of-rise, which helps in environments where smoke may be present from non-fire sources. It also provides a heat-only alarm if smoke detection is disabled.
Can I replace a Series 65 detector with a Soteria detector without changing the base? No, the mechanical mounting and electrical connections are different. You must replace the base as well. The Soteria range uses a different base design, so a full replacement is required.
Why does my detector false alarm in the kitchen? Optical detectors are sensitive to cooking aerosols, such as steam and oil vapours. Even though they are less prone to false alarms than ionisation detectors, they can still be triggered by close-range cooking. For kitchens, use a heat detector or an optical detector with a heat sensor and set the alarm threshold higher.
How often should I clean the detector? In normal office environments, cleaning once a year is sufficient. In dusty or industrial areas, clean every 6 months. Use a vacuum cleaner with a soft brush or blow out the chamber with compressed air. Do not use water or solvents.