Apollo Optical Smoke Detector: How It Works & Models

Updated November 21, 2026

The Apollo optical smoke detector is a type of fire alarm sensor that uses a light-scattering principle to detect smoke particles, and it is a core product line from Apollo Fire Detectors, a UK-based manufacturer widely used in commercial and industrial fire systems. These detectors are known for their reliability, low false-alarm rates, and compatibility with Apollo’s addressable and conventional control panels.

Background and History

Apollo Fire Detectors, founded in 1980 in Havant, England, has become one of the world’s largest manufacturers of fire detection equipment. The company developed its first optical smoke detectors in the 1980s, and the technology has evolved through several series. The most notable families include the Series 65 (conventional), the XP95 (addressable), and the Discovery (advanced addressable) ranges. Each series was designed to meet specific market needs, from basic standalone units to sophisticated detectors with drift compensation and multi-sensor capabilities. Apollo’s detectors are certified to European and international standards, including EN 54-7 (for smoke detectors) and UL 268 (for the North American market).

How Optical Smoke Detection Works

An optical smoke detector, also called a photoelectric detector, uses a light source (typically an infrared LED) and a light-sensitive sensor (a photodiode) placed in a chamber. In normal conditions, the light from the LED is directed away from the sensor, so no light hits it. When smoke enters the chamber, the smoke particles scatter the light, and some of that scattered light reaches the photodiode. When the amount of light reaching the sensor exceeds a threshold, the detector triggers an alarm. This principle is called light scattering or the Tyndall effect. Unlike ionization detectors, which detect small particles from flaming fires, optical detectors are more sensitive to larger particles produced by smoldering fires, such as those from overheated wiring or upholstery. This makes them excellent for general area protection but less ideal for fast-flaming fires.

Apollo Detector Series and Models

Apollo offers several distinct ranges, each with specific features and applications.

  • Series 65: A conventional detector range that operates on a simple two-wire loop. It includes the 65A optical smoke detector, which is widely used in small commercial and residential applications. It has a replaceable optical chamber and is known for its ease of maintenance.
  • XP95: An addressable detector range that communicates digitally with the control panel. The XP95 Optical Smoke Detector (model 55000-200) is a common choice for larger installations. It supports a wide operating voltage and has a built-in status LED.
  • Discovery: An advanced addressable range that offers features like drift compensation, which adjusts sensitivity over time to prevent false alarms due to dust accumulation. The Discovery Optical Smoke Detector (model 58000-200) also supports a heat sensor variant (the Discovery Optical Heat) for dual-sensing.
  • S200: A newer, cost-effective addressable range that still uses Apollo’s core technology but with a simpler design, suitable for budget-conscious projects.

Choosing the Right Apollo Detector

Selecting the correct Apollo optical smoke detector depends on your system type, environment, and local fire codes.

  1. Determine your system type: Check if your fire alarm control panel is conventional or addressable. Conventional systems use zones, while addressable systems identify each device individually. Apollo’s Series 65 is conventional; XP95, Discovery, and S200 are addressable.
  2. Consider the environment: For areas with high dust, humidity, or steam (like kitchens or bathrooms), a standard optical detector may cause nuisance alarms. Apollo offers models with enhanced sealing or combined heat/smoke sensors to reduce false alarms.
  3. Check compatibility: Ensure the detector is compatible with your specific control panel brand and model. Apollo detectors work with Apollo’s own panels, but many third-party panels also support Apollo protocol. Always verify with the panel manufacturer’s compatibility list.
  4. Review standards: In many regions, the installation must comply with national standards (e.g., BS 5839 in the UK, NFPA 72 in the US). These standards dictate where detectors are placed and what type is required for different areas.

Common Problems and Troubleshooting

Like all electronic devices, Apollo optical smoke detectors can experience issues. The most common is false alarms, often caused by dust, insects, or steam. Apollo detectors have a removable optical chamber that can be cleaned with a vacuum or compressed air. Another common issue is a detector not responding, which can be due to wiring faults, incorrect address settings (in addressable systems), or a faulty base. Many Apollo detectors feature a remote LED indicator and a test switch for local testing. If a detector repeatedly alarms without smoke, it may need to be replaced, as the sensor can degrade over time. Always consult the user manual or a qualified technician for specific troubleshooting.

Comparison with Ionization and Heat Detectors

To understand where Apollo optical detectors fit, it helps to compare them with other types.

  • Optical vs. Ionization: Optical detectors are better at detecting slow, smoldering fires and are less prone to false alarms from cooking fumes. Ionization detectors respond faster to flaming fires but contain a small radioactive source, which some users find undesirable. Many modern systems use both types for comprehensive coverage.
  • Optical vs. Heat: Heat detectors respond to temperature changes, not smoke, so they are immune to false alarms from smoke or dust. However, they are slower to alert and are typically used in areas where smoke detectors are unsuitable, like garages or boiler rooms. Apollo also makes combined optical-heat detectors that use both sensing elements to reduce false alarms while maintaining sensitivity.

Installation and Maintenance Best Practices

Proper installation and maintenance are crucial for reliable operation.

  • Placement: Install detectors on ceilings, at least 30 cm away from walls and light fixtures. Avoid placing them near air vents, doors, or windows where airflow can dilute smoke.
  • Spacing: Follow local codes for maximum spacing (typically 7.5 meters apart in corridors, but this varies).
  • Testing: Test each detector monthly using the test button or a test aerosol. Clean the optical chamber annually, or more often in dusty environments.
  • Replacement: Apollo recommends replacing detectors after 10 years of service, as sensor sensitivity can decline. Check the manufacturing date on the device.

Cost and Availability

Apollo optical smoke detectors are competitively priced. A single Series 65 detector costs roughly $20–$40, while addressable models like the XP95 or Discovery can range from $30 to $60, depending on the supplier and quantity. Bases, which are required for mounting, add $5–$15 each. For a typical small office with 10 detectors, the total cost for detectors and bases might be $300–$700. They are widely available through fire safety distributors and online retailers. Always purchase from authorized dealers to ensure genuine products and warranty support.

Safety and Standards Compliance

Apollo detectors are designed to meet strict safety standards. In Europe, they are CE-marked and comply with EN 54, the mandatory standard for fire detection and alarm systems. In the US, Apollo has a line of detectors certified to UL 268. These certifications ensure that the detectors have been tested for sensitivity, false alarm resistance, and durability. When installing any fire alarm system, it is essential to have it designed and installed by a qualified professional who understands local codes. Regular testing and maintenance are not just recommended—they are often required by law for commercial buildings.

Frequently Asked Questions

How do I reset an Apollo optical smoke detector after an alarm?

To reset, you typically need to press the reset button on the control panel or briefly remove power from the detector. On addressable systems, the panel may have a ‘reset’ command. If the detector remains in alarm, it may still be sensing smoke or there may be a fault. Always ensure the area is clear of smoke before resetting.

Can I use an Apollo optical detector in my home?

Yes, but Apollo primarily targets commercial and industrial systems. For home use, you would need a compatible control panel, which is usually more complex than a standard residential smoke alarm. If you have a home fire alarm system with an Apollo-compatible panel, you can use these detectors. Otherwise, residential-grade photoelectric detectors are simpler and more cost-effective.

What is the difference between Apollo XP95 and Discovery?

The XP95 is an older, simpler addressable range, while Discovery offers advanced features like drift compensation, which automatically adjusts sensitivity to dust buildup, and supports multi-sensor (optical/heat) models. Discovery also has a wider operating voltage range and is designed for more demanding applications. In practice, Discovery is often used in larger or more critical installations.

How often should I clean my Apollo detector?

Apollo recommends cleaning the optical chamber at least once a year, but in dusty or dirty environments, you may need to clean it more frequently, perhaps every 6 months. Use a vacuum cleaner with a soft brush attachment to remove dust from the chamber. Do not use water or cleaning solvents, as they can damage the sensor.

Why does my Apollo detector keep giving false alarms?

False alarms are commonly caused by dust, insects, steam, or cooking fumes. Check if the detector is located near a kitchen, bathroom, or air vent. Clean the optical chamber and ensure the detector is not obstructed. If the problem persists, the detector may be faulty and should be replaced.

Can I replace a Series 65 detector with an XP95 on the same loop?

No, Series 65 is conventional and XP95 is addressable; they use different communication protocols. You cannot mix them on the same loop. You would need to change the entire loop or use a different panel that supports both, which is rare. Always match the detector type to your system’s protocol.