Apollo XP95 Smoke Detector: How It Works and Where to Use It

Updated November 21, 2026

The Apollo XP95 smoke detector is a widely used analogue-addressable fire detection device manufactured by Apollo Fire Detectors, designed for use in commercial and industrial fire alarm systems. It works by continuously measuring smoke levels in the air and reporting a precise value to a control panel, which then decides whether to raise an alarm based on programmable thresholds.

Background: The XP95 Family and Its Place in Fire Detection

The XP95 range was introduced by Apollo in the late 1980s and became one of the most common fire detection platforms in the UK and many other countries. It was designed as a fully analogue-addressable system, meaning each detector has a unique address and communicates with a central control panel over a two-wire loop. This was a significant step up from older conventional systems, where detectors were grouped into zones and could only indicate a general area of alarm.

XP95 detectors are part of a complete ecosystem that includes smoke detectors, heat detectors, manual call points, sounders, and interface units. The system uses a protocol that allows the control panel to poll each device in turn, requesting its current smoke level or temperature reading. This constant communication enables more sophisticated features such as drift compensation, pre-alarm warnings, and the ability to identify which specific detector has activated.

How the XP95 Smoke Detector Works

The XP95 optical smoke detector uses a light-scattering principle. Inside the detector chamber, an infrared light-emitting diode (LED) shines light at an angle away from a photodiode sensor. Under normal conditions, the light beam passes without hitting the sensor. When smoke enters the chamber, the smoke particles scatter the light, causing some of it to reach the photodiode. The amount of scattered light is proportional to the smoke density, and this value is transmitted to the control panel as an analogue reading.

This design is particularly effective at detecting slow-burning, smouldering fires that produce large visible smoke particles, such as those from overheated wiring or upholstery. The XP95 also has a version with a carbon monoxide (CO) sensor, called the XP95 CO smoke detector, which can detect both smoke and CO gas. This dual-sensor approach helps reduce false alarms from cooking fumes while still responding quickly to real fires.

Choosing the Right XP95 Smoke Detector

Selecting the correct XP95 smoke detector depends on the environment and the type of fire risk. Apollo offers several variants within the XP95 range:

  • Optical smoke detector (58000-600): The standard model, best for general areas where smouldering fires are likely.
  • Ionisation smoke detector (58000-500): More sensitive to fast-flaming fires with small particles, but less common today due to the radioactive material inside and higher false alarm rates.
  • CO smoke detector (58000-700): Combines optical sensing with a carbon monoxide cell, useful in kitchens or areas with high humidity where steam can cause false alarms.
  • Heat detector (58000-400): Not a smoke detector, but part of the same range, used in dusty or smoky environments where smoke detection is unsuitable.

When choosing, consider the ceiling height, air flow, and the presence of steam, dust, or fumes. For example, a standard optical detector should not be installed directly above a cooking appliance. The control panel must be compatible with the XP95 protocol, so check the manufacturer’s list of approved panels before purchase.

Common Problems and Maintenance

Like all electronic devices, XP95 detectors can develop issues over time. The most common problems are:

  • False alarms caused by steam, dust, or insects entering the sensing chamber. Regular cleaning and the use of insect-resistant versions can help.
  • Drift compensation failure – the detector’s software adjusts for gradual dirt build-up, but if the contamination becomes too heavy, the detector may go into fault. This is indicated by a flashing amber LED.
  • Address faults – if a detector is replaced, it must be re-addressed correctly, or the panel will not recognise it.
  • End-of-life – most detectors have a recommended service life of around 10 years, after which the sensor may become unreliable.

Regular testing is essential. Use a test aerosol specifically designed for optical smoke detectors, not a real flame or cigarette smoke, which can contaminate the chamber. The detector should be cleaned with a vacuum cleaner or soft brush, never water or solvents.

Comparison with Other Apollo Detectors

Apollo also makes the newer S95 and Discovery ranges, which use the same mechanical base but different electronics. The S95 is a direct replacement for XP95 in many systems, offering similar functionality with improved components. The Discovery range adds more advanced features like multi-criteria sensing and adjustable sensitivity via the panel, but it requires a Discovery-compatible control panel.

For most existing XP95 installations, the S95 is the natural upgrade path because it fits the same base and uses the same protocol. The Discovery detectors are not backward-compatible with XP95 panels. If you are designing a new system, the Discovery range offers more flexibility, but the XP95 remains a reliable and cost-effective choice for many applications.

Cost and Availability

Prices for XP95 smoke detectors vary by region and supplier, but they generally fall in the mid-range for commercial fire detectors. A single optical detector typically costs between $20 and $40, with the CO version slightly more. Replacement bases, which are required for mounting, cost a few dollars each. The detectors are widely available from fire safety distributors and online electrical suppliers.

Because the XP95 range has been in production for decades, spare parts and replacements are easy to find. However, check the production date on the detector – Apollo marks the year and week on the label. If a detector is older than 10 years, it should be replaced rather than repaired.

Safety and Standards Compliance

XP95 detectors are certified to EN 54-7, the European standard for smoke detectors, and many models also meet other international standards. They are designed for indoor use only, with an operating temperature range of -20°C to +60°C. The detector should be installed according to local fire codes, typically with a maximum spacing of 7.5 metres between detectors on flat ceilings, and at least 0.5 metres from walls and light fittings.

It is crucial to note that these detectors are part of a fire alarm system and must be connected to a compatible control panel. They are not standalone devices. Always follow the manufacturer’s installation instructions and have the system commissioned by a qualified fire alarm engineer. Regular servicing, including a functional test and sensitivity check, should be carried out at least once a year.

Frequently Asked Questions

Can I use an XP95 smoke detector with my existing alarm panel?
Only if your panel supports the XP95 protocol. Check the panel’s manual or contact the manufacturer. Most Apollo-compatible panels from the 1990s and 2000s will work, but newer panels may require S95 or Discovery detectors.

What is the difference between optical and ionisation smoke detectors?
Optical detectors use light scattering to detect larger smoke particles from smouldering fires. Ionisation detectors use a small radioactive source to detect smaller particles from fast-flaming fires. Optical detectors are generally preferred because they have fewer false alarms and contain no radioactive material.

How do I reset an XP95 detector after an alarm?
You cannot reset the detector itself. The control panel must be reset, usually by entering a code or pressing a reset button. If the detector remains in alarm after a reset, it may be contaminated or faulty.

Why is my XP95 detector flashing red but not alarming?
A flashing red LED indicates that the detector is in alarm or has been activated. If the panel is not showing an alarm, the detector may have a fault, or the panel may be in a test mode. Check the panel display for error messages.

How often should I test my XP95 smoke detector?
At least once a year as part of a full fire alarm test, and more frequently in high-risk environments. Use a suitable test aerosol and follow the panel’s test procedure. Never use an open flame.