Ares makeup air unit refers to the line of commercial and industrial makeup air units manufactured by Ares, a brand known for ventilation equipment used in restaurants, warehouses, and other facilities that exhaust large volumes of air. These units replace the air that is pulled out by exhaust fans, preventing negative pressure, backdrafts, and uncomfortable drafts. This article explains what an Ares makeup air unit does, how to select one, common installation issues, and answers frequently asked questions.
Why Makeup Air Is Necessary
Every building with mechanical exhaust—kitchen hoods, bathroom fans, dryers, or industrial processes—removes air from the interior. If that air is not replaced, the building develops negative pressure. Negative pressure causes several problems: doors become hard to open, exhaust fans lose efficiency, and combustion appliances like water heaters or furnaces can backdraft, pulling carbon monoxide into living spaces. Makeup air units solve this by introducing fresh, tempered (heated or cooled) outdoor air to balance the pressure. In commercial kitchens, for example, a 2,000 CFM exhaust hood requires roughly 2,000 CFM of makeup air to operate safely and efficiently.
What an Ares Makeup Air Unit Includes
Ares makeup air units are typically roof-mounted or wall-mounted packaged units. A standard unit contains a motorized fan, a fresh air intake hood, a filter, and either a gas burner, electric heater, or no heat (for mild climates). Some models include a motorized damper that opens only when the exhaust system runs, preventing cold air from entering when the unit is off. Ares units are often specified for restaurant exhaust systems because they are designed to work with commercial kitchen hoods that remove large volumes of air. The units are available in various CFM (cubic feet per minute) ratings, commonly from 1,000 to 10,000 CFM, and can be configured for horizontal or vertical discharge.
How to Choose the Right Size
Sizing a makeup air unit is a matter of matching the exhaust airflow. The general rule is that makeup air should equal 80–100% of the exhaust air volume. For example, if a kitchen hood exhausts 4,000 CFM, the makeup air unit should deliver at least 3,200 to 4,000 CFM. Oversizing wastes energy; undersizing causes negative pressure. To determine the exact requirement, you need the total exhaust CFM from all exhaust fans that operate simultaneously. Many local building codes require a professional engineer or HVAC contractor to perform this calculation. Also consider the temperature rise needed: a gas-fired unit can raise outdoor air by 40–100°F, while electric heaters are less powerful but simpler to install.
Installation and Ductwork Considerations
Installation location matters. A makeup air intake must be placed away from exhaust vents, garbage areas, and loading docks to avoid pulling contaminated air back inside. The intake should be at least 10 feet from any exhaust outlet, according to most mechanical codes. Ductwork must be sized to keep air velocity below 1,500 feet per minute to reduce noise and pressure drop. Roof-mounted units require a curb and proper flashing to prevent leaks. Wall-mounted units need a structural frame to support the weight. Always follow the manufacturer’s installation manual and local codes. A common mistake is installing the intake too close to the exhaust hood’s discharge, which recycles grease-laden air into the building.
Common Problems and Troubleshooting
Owners report several recurring issues with makeup air units, including Ares models:
- Insufficient airflow: Check the filters for clogging, the damper for proper opening, and the fan belt tension.
- Cold drafts: The heater may be undersized or the thermostat set too low. Verify the temperature rise matches the design.
- Unit runs but no air: The motorized damper may be stuck closed, or the control interlock with the exhaust fan is faulty.
- Odors entering: The intake is pulling in exhaust from nearby vents—relocate the intake or add a longer duct.
- Excessive noise: Duct velocity is too high, or the fan is unbalanced. Reduce fan speed or add sound attenuation.
Regular maintenance includes cleaning or replacing filters every 1–3 months in greasy environments, checking the burner flame annually, and lubricating fan bearings.
Costs and Energy Efficiency
The purchase price of an Ares makeup air unit ranges from roughly $3,000 to $15,000 depending on CFM, heating type, and features. Installation adds another $2,000–$8,000, including ductwork, electrical, and gas connections. Operating costs depend on how often the unit runs and the fuel type. Gas-fired units are usually cheaper to operate than electric in most regions. To reduce energy use, choose a unit with a variable-speed fan and a damper that closes when not needed. Some models include energy recovery wheels that transfer heat from exhaust air to incoming air, cutting heating costs by up to 60%, though these are more expensive upfront.
Comparison with Other Makeup Air Solutions
An Ares unit is one option among several. Alternatives include:
- Passive vents: Simple grilles that let outdoor air in without a fan. Cheap but do not temper the air, causing drafts and higher heating bills.
- Dedicated outdoor air systems (DOAS): Larger, more complex units that also handle dehumidification, often used in whole-building ventilation.
- Exhaust-only with transfer air: Using air from adjacent spaces instead of outdoors, common in buildings with open floor plans.
- Other brands: Companies like Greenheck, CaptiveAire, and Modine make similar units. Ares units are often chosen for price competitiveness and availability through restaurant equipment suppliers.
The best choice depends on climate, building layout, and budget. For a commercial kitchen with a high exhaust rate, a dedicated heated makeup air unit like an Ares is typically the standard solution.
Safety and Code Requirements
Makeup air units must comply with mechanical and fire codes. In commercial kitchens, the makeup air must not interfere with the exhaust hood’s ability to capture smoke and grease. The intake must be screened to prevent birds and rodents. Gas-fired units require proper combustion air and venting to the outside. Always install carbon monoxide detectors if any combustion appliance is present. Also, the unit must be interlocked with the exhaust fan so that makeup air only runs when exhaust is running—this prevents pressurizing the building when the hood is off. Local codes often require a licensed HVAC contractor to perform the installation and a final inspection.
Frequently Asked Questions
Can I install an Ares makeup air unit myself? Not recommended. It involves gas or electric connections, structural mounting, and code compliance. Most jurisdictions require a licensed professional for the gas and electrical work, and improper installation can void the warranty or create safety hazards.
How often should I replace the filters? In a typical restaurant, check monthly and replace when visibly dirty—usually every 1–3 months. In cleaner environments, every 6 months is often sufficient. Dirty filters reduce airflow and strain the motor.
Will a makeup air unit increase my heating bill? Yes, because it brings in cold outdoor air that must be heated. However, the cost is far less than the damage from negative pressure, such as backdrafting or structural issues. Energy recovery options can reduce this cost.
What does CFM mean and why does it matter? CFM stands for cubic feet per minute, the volume of air the unit moves. It must match your exhaust airflow. If you don’t know your exhaust CFM, a contractor can measure it with a hood anemometer.
Can a makeup air unit cool the air in summer? Most standard units only heat or provide unheated outdoor air. Some models can be fitted with evaporative cooling or refrigeration, but that is rare and expensive. In summer, the unit simply brings in outdoor air without heating it.
Is an Ares unit the same as a roof top unit (RTU)? No. An RTU heats and cools the building’s indoor air. A makeup air unit only brings in fresh outdoor air to replace exhausted air, though some combined units do both. They serve different purposes.