OneStopList

Gods and goddesses

Ares Home Sleep Test: How It Works & What to Expect

Updated November 20, 2026

The Ares home sleep test is a portable device used to diagnose obstructive sleep apnea by measuring airflow, breathing effort, oxygen levels, and heart rate while you sleep in your own bed. It is a Type III home sleep apnea test (HSAT) that provides a clinical-grade assessment without requiring an overnight stay in a sleep lab.

What the Ares Device Measures

The Ares (Apnea Rate in Sleep) device is worn on the forehead and uses a small sensor assembly that rests against your face. Unlike many other home sleep tests that use finger probes and chest belts, the Ares consolidates its sensors into a single head-mounted unit. It records:

  • Nasal airflow via a pressure cannula to detect pauses or reductions in breathing
  • Snoring through an acoustic microphone
  • Oxygen saturation (SpO2) using a reflectance oximeter on the forehead
  • Pulse rate from the same oximeter
  • Head position and movement to help interpret sleep posture
  • Effort via a sensor that detects the subtle movements of the head caused by breathing effort

Because it does not measure brain waves (EEG) or leg movements, it cannot stage sleep or detect conditions like central sleep apnea with the same precision as an in-lab polysomnogram. It is specifically designed to identify obstructive events, which are the most common form of sleep apnea.

How the Test Is Administered

The Ares test is typically ordered by a physician or a sleep specialist after a clinical evaluation. The process usually follows these steps:

  1. You receive the device from a sleep center, a durable medical equipment provider, or by mail.
  2. A technician or clinician instructs you on how to position the device on your forehead and how to turn it on before bed.
  3. You sleep with the device for one night, or sometimes two, depending on the protocol.
  4. In the morning, you return the device or ship it back to the sleep center.
  5. The data is downloaded and scored by a sleep technologist, then interpreted by a board-certified sleep physician.

The device is worn with a soft headband that holds it in place. It is lightweight and designed to be comfortable enough for most people to sleep on their back, side, or stomach without significant disturbance.

Who Is a Good Candidate for the Ares Test

Home sleep tests are not appropriate for everyone. The Ares test is generally recommended for adults with a high pretest probability of moderate to severe obstructive sleep apnea, based on symptoms such as loud snoring, witnessed apneas, gasping during sleep, and daytime sleepiness. It is not recommended for people with:

  • Severe cardiopulmonary disease (e.g., congestive heart failure, COPD)
  • Neuromuscular disorders that affect breathing
  • Suspected central sleep apnea or hypoventilation
  • Chronic opioid use, which can suppress breathing
  • Inability to sleep without turning over frequently, or intolerance of wearing a head-mounted device

If you have any of these conditions, an in-lab polysomnogram is usually the safer and more accurate choice. The physician decides whether a home test is suitable based on your medical history and risk factors.

Interpreting the Results

The Ares device produces a report that includes an apnea-hypopnea index (AHI), which is the average number of apneas (complete pauses) and hypopneas (partial reductions) per hour of sleep. The scoring criteria follow the American Academy of Sleep Medicine (AASM) guidelines, though the exact definitions may vary slightly by the software version used.

An AHI below 5 is considered normal in adults. An AHI of 5–15 is mild sleep apnea, 15–30 is moderate, and over 30 is severe. The report also includes oxygen desaturation index (ODI), the lowest oxygen level recorded, and the percentage of time spent below 90% oxygen saturation. These metrics help the physician determine the severity and recommend treatment, which may include CPAP, oral appliances, positional therapy, or lifestyle changes.

One limitation is that the Ares does not measure total sleep time directly. It estimates sleep time based on periods of regular breathing and movement, which can slightly over- or under-estimate the AHI compared to an in-lab test that uses EEG to confirm sleep.

Comparison with In-Lab Polysomnography

The in-lab polysomnogram (PSG) is the gold standard for diagnosing all sleep disorders. It records brain waves, eye movements, muscle tone, heart rhythm, breathing, airflow, and leg movements, all under direct observation by a technologist. The Ares test, being a Type III device, is less comprehensive. It cannot diagnose:

  • Central sleep apnea (it may flag events but cannot reliably distinguish central from obstructive without an esophageal pressure sensor)
  • Periodic limb movement disorder
  • REM sleep behavior disorder
  • Narcolepsy or other hypersomnias

However, for straightforward obstructive sleep apnea, the Ares has been shown in clinical studies to have reasonable sensitivity and specificity compared to PSG, though false negatives can occur in mild cases. If the home test is negative but symptoms persist, a physician will often order an in-lab study.

Cost and Insurance Coverage

The cost of an Ares home sleep test varies widely. Without insurance, it can range from roughly $150 to $500, depending on the provider and whether it includes physician interpretation. Many insurance plans, including Medicare, cover home sleep apnea testing when ordered by a physician for suspected obstructive sleep apnea. Medicare covers HSATs for beneficiaries who meet specific criteria, such as having signs of OSA and no significant comorbid conditions. It is important to check with your insurer beforehand to confirm coverage and whether the test must be obtained from an in-network provider.

Common Problems and Limitations

Users sometimes report issues with the Ares device, including:

  • Discomfort or headache from the headband, especially if worn too tight
  • Sensor displacement during the night, which can cause signal loss
  • Inability to fall asleep with the device, leading to an invalid test
  • Skin irritation from the adhesive or the oximeter sensor

If the test fails due to poor data quality, most providers will allow one repeat attempt. If a second attempt fails, an in-lab study is typically recommended. Some people also find that the forehead sensor is more noticeable than a finger probe, though most adapt within a night.

Frequently Asked Questions

Is the Ares home sleep test accurate?

Yes, for detecting moderate to severe obstructive sleep apnea, the Ares has good agreement with in-lab polysomnography in clinical validation studies. It is less reliable for mild sleep apnea and may miss some events because it does not measure brain waves to confirm sleep. If your symptoms are strong but the Ares result is normal, your doctor may still recommend an in-lab test.

How long does it take to get results?

After you return the device, the data is downloaded and scored by a sleep technologist, then reviewed by a physician. The turnaround is typically 3 to 7 business days, though some clinics offer faster reporting. You will usually receive a follow-up appointment or a phone call to discuss the results and treatment options.

Can I use the Ares test if I have insomnia?

It is possible, but if you cannot sleep with the device on, the test may be invalid. The device does not measure sleep stages, so it relies on you actually sleeping. If you have severe insomnia or anxiety about wearing a device, an in-lab test with a technician may be more appropriate.

Do I need a prescription to get an Ares test?

Yes, home sleep apnea tests are medical devices that require a prescription from a licensed healthcare provider. You cannot order one directly without a physician’s order. A doctor will first evaluate your symptoms and risk factors to decide if a home test is appropriate.

What happens if the test shows sleep apnea?

Your physician will discuss treatment options based on the severity. For moderate to severe cases, continuous positive airway pressure (CPAP) is the most common treatment. For mild cases, a mandibular advancement device (oral appliance), positional therapy, or weight loss may be recommended. The Ares test result alone does not prescribe treatment; it is a diagnostic tool.

Is the Ares test covered by Medicare?

Medicare covers home sleep apnea testing for beneficiaries who meet specific criteria, including symptoms of OSA and no significant comorbidities like heart failure or COPD. The test must be ordered by a physician and performed by a Medicare-approved supplier. Coverage is not automatic, so confirm with your provider before scheduling.